Terminal Block Function:
1. T1 DC + 24V power input
2. T2 power input DC0V
3. T3 control signal input 0V
4. T4 control signal (n) 0 ~ 10V, input positive voltage value T8, T9 foot OUT A output, enter a negative voltage value T10, T11 output pin OUT B
5. T5 Ground
6. T6 + 10V 3mA
7. T7 -10V 3mA
8. T8 A group output + V
9. T9 A group output 0V
10.T10 B group output 0V
11.T11 Group B output + V
Pin wiring diagram:

Potentiometer adjustment Description:
1. VR1: Imax A group A, current intensity multiple ratio ratio value adiustment,increased clockwise.
2. VR2: Imin A group A starting current value intensity adjustment. increased clockwise.
3. VR3: Imax B group B current intensity multiple ratio ratio value adiustment,increased clockwise.
4. VR4: Imin B group B starting current value intensity adjustment. increased clockwise.
5. VR5: UP Timer group A/ B, up time slope adjustment 0.1 ~ 5S increased clockwise.
6. VR6: DN Timer group A/ B,down time slope adjustment, 0.1 ~ 5S increased clockwise.
7. VR7: Frequence group A/ B, frequency value adjustment, 50 ~ 500HZ, increased clockwise.
SIN-1 hydraulic double output proportional valve selection model specifications SIN-1 - Code 1
| Code1 |
| BOX |
Circuit control panel is equipped with outer protecive box. |
| BLK |
Circuit control board is equipped with Z-shaped bracket. |