Terminal Block Function:
1. T1 DC + 24V power input
2. T2 power input DC0V
3. T3 control signal input 0V
4. T4 control signal (n) 0 ~ 10V, input positive voltage value T6, T7 foot OUT A output, input load voltage T8, T9 foot OUT B output
5. T5 Ground
6. T6 + 10V 3mA
7. T7 -10V 3mA
8. T8 A group output + V
9. T9 A group output 0V
10.T10 B group output 0V
11.T11 Group B output + V
Pin wiring diagram:

Potentiometer adjustment Description:
1. VR1: Imax A group A, current intensity multiple ratio value adjustment, increased clockwise.
2. VR2: Imin A group A,starting current value intensity adjustment. increased clockwise.
3. VR3: UP Timer group A, up time slope adjustment 0.1 ~ 5S increased clockwise.
4. VR4: DN Timer A group A,down time slope adjustment, 0.1 ~ 5S increased clockwise.
5. VR5: Imax B group B, current intensity multiple ratio value adjustment, increased clockwise.
6. VR6: Imin B group B,starting current value intensity adjustment. increased clockwise.
7. VR7: Time B group B,up time slope adjustment 0.1 ~ 5S increased clockwise.
8. VR8: DN Timer B group B,down time slope adjustment, 0.1 ~ 5S increased clockwise.
9. VR9: Frequence A group A, frequency adjustment, 50 ~ 500HZ
10. VR10: Frequence B group B, frequency adjustment, 50 ~ 500HZ
SIN-2 hydraulic double output proportional valve selection model specifications SIN-2 - Code 1
| Code1 |
| BOX |
Circuit control panel is equipped with outer protecive box. |
| BLK |
Circuit control board is equipped with Z-shaped bracket. |